VAREOPLYSNINGER
Kilometertal
1.320 Timer
VIN
231 kVA/185 kW Rated 3 Phase Output, 208 V / 120 V Rated Voltage, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Bottom Mounted Fuel Tank, Linz Electric PR028S C/4 Generator, 2021 US EPA Label, FPT 6 Cylinder 223 hp 6.7 L Diesel Engine, Requires Diesel Exhaust Fluid, T/A Trailer, Lunette Ring, Electric Brakes
***Trailer that unit is seen on and other items seen in background are Not included in sale.***

**The seller will require 2 business days notice to pick these units up. They are located at un-manned yards in remote areas. Buyer MUST contact Brad Welch at 253-525-0435 to arrange pickup.**

Eftersynsrapport



Bemærk venligst, at du som køber er ansvarlig for at gennemse hele eftersynsrapporten, når du evaluerer en vare.


Generelt udseende
Beskrivelse Bedømmelse Detaljer  
Unit Serial Number 20.64088 Klik her for at åbne biller og videoer af denne vare.  
Motor Vehicle Safety Standards Label Yes Klik her for at åbne biller og videoer af denne vare.  
Maling Klik her for at åbne biller og videoer af denne vare.  
Metalplader (fiberglas) tilstand Klik her for at åbne biller og videoer af denne vare.  
Motorkappe, isolering og bundkar Klik her for at åbne biller og videoer af denne vare.  
(17)


Generator Electrical
The generator was not load checked during the inspection. IronPlanet does not guarantee the generators ability to run at its full rated kW output.
Beskrivelse Bedømmelse Detaljer  
Afbryderknap Functional Klik her for at åbne biller og videoer af denne vare.  
Kabler og forbindelser Klik her for at åbne biller og videoer af denne vare.  
Nødafbryderknap Operational Klik her for at åbne biller og videoer af denne vare.  
Opsamlingsbeholder Not operationally checked Klik her for at åbne biller og videoer af denne vare.  
Begrænset funktionstjek The main components appear to be in place. The generator is producing electricity.
(5)


Control Station - Small
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Beskrivelse Bedømmelse Detaljer  
Måler Operational Klik her for at åbne biller og videoer af denne vare.  
Engine Oil Pressure The gauge registers in the operating range. Klik her for at åbne biller og videoer af denne vare.  
Fault Indicator Lights Operational Klik her for at åbne biller og videoer af denne vare.  
Timetæller (før inspektion) 1320.40 hrs Klik her for at åbne biller og videoer af denne vare.  
Timetæller 1320 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Klik her for at åbne biller og videoer af denne vare.  
Begrænset funktionstjek The main components are in place and operational as noted. Klik her for at åbne biller og videoer af denne vare.  
(7)


Engine
Beskrivelse Bedømmelse Detaljer  
Emission Label Photo Klik her for at åbne biller og videoer af denne vare.  
Blow-by No noticeable vapor or pressure Klik her for at åbne biller og videoer af denne vare.  
Starter Operational
Brændstofsystem Operational Klik her for at åbne biller og videoer af denne vare.  
Udstødningssystem Klik her for at åbne biller og videoer af denne vare.  
Køler Klik her for at åbne biller og videoer af denne vare.  
Oil Leaks No dripping leaks Klik her for at åbne biller og videoer af denne vare.  
Fuel Leaks No dripping leaks
Cooling System Leaks No dripping leaks
Engine - Left Side Klik her for at åbne biller og videoer af denne vare.  
Engine - Right Side Klik her for at åbne biller og videoer af denne vare.  
DEF / AdBlue Tank Klik her for at åbne biller og videoer af denne vare.  
Limited Function Check The engine started and ran. Klik her for at åbne biller og videoer af denne vare.  
(10)


v2 Chassis - Generator
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Beskrivelse Bedømmelse Detaljer  
Akseltilstand Klik her for at åbne biller og videoer af denne vare.  
Trailer Brake Type Electric Brakes
Brake Function Check The brakes were not operationally checked
Left Front Tire Klik her for at åbne biller og videoer af denne vare.  
Left Rear Tire Klik her for at åbne biller og videoer af denne vare.  
Right Rear Tire Klik her for at åbne biller og videoer af denne vare.  
Right Front Tire Klik her for at åbne biller og videoer af denne vare.  
Hjultilstand
Lejestift
Fjedre/Hænger tilstand Klik her for at åbne biller og videoer af denne vare.  
Tunge/tilkobling tilstand No visible damage Klik her for at åbne biller og videoer af denne vare.  
Lygter / ledningsføring tilstand Not operationally checked Klik her for at åbne biller og videoer af denne vare.  
Rammeskinner / Hovedbjælker tilstand No visible damage Klik her for at åbne biller og videoer af denne vare.  
Landingsstel / Næsehjul med kip Klik her for at åbne biller og videoer af denne vare.  
Brændstofbeholdertilstand Klik her for at åbne biller og videoer af denne vare.  
(25)
 

Olieprøveanalyse
  engine
date of analysis Mar 14, 2024
Silicon 4.71 PPM
Tin 2.3 PPM
Silver 0 PPM
Aluminum 1.8 PPM
Chromium 0 PPM
Lead 0.62 PPM
Copper 3.35 PPM
Nickel 0.5 PPM
Iron 9.42 PPM
Glycol NEG
Water NEG
Fuel <5%
Tvister:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.