Forrige Næste
Auktion er lukket den
04-04-24
IKKE SOLGT
VAREOPLYSNINGER
Måleraflæsning
6.200 Timer
Serienummer
Enclosed Cab, Air Conditioner, 2 Stage Mast, 372 in Max Lift Height, 2017 US EPA Label, Cummins QSM11 330 hp Diesel Engine

Eftersynsrapport



Bemærk, at du byder på en vare, der udbydes uden IronClad-forsikring®. Kun grundlæggende oplysninger om varens tilstand stilles til rådighed for dig, når du skal foretage din købsbeslutning.
 
Model Description
Beskrivelse Detaljer
 
Functionality
Beskrivelse Detaljer
Engine The engine started and ran.
Drivetrain The drivetrain engages in forward and reverse.
Hydraulics The hydraulic system could not be operationally checked.
Deficiencies Deficient Components/Systems Include but are not limited to: Does not stay in gear

Varen tilbydes som beset, dvs. uden IronClad Assurance, og en køber har ikke ret til at gøre indsigelser mod varens stand IronPlanet kan ikke holdes ansvarlig for stand eller beskrivelse af denne vare. Denne vare er ikke omfattet af den beskyttelse, der tilbydes af IronClad Assurance. En køber har IKKE ret til at gøre indsigelser mod denne vare.


Generelt udseende
Beskrivelse Bedømmelse Detaljer  
Operation Video Klik her for at åbne biller og videoer af denne vare.  
CE-mærke No CE mark found
Hour Meter / Odometer 6200 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Klik her for at åbne biller og videoer af denne vare.  
(2)


Control Station Photos
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Beskrivelse Bedømmelse Detaljer  
(7)


Engine
Beskrivelse Bedømmelse Detaljer  
(10)


Drivetrain Photos
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Beskrivelse Bedømmelse Detaljer  
(2)


Hydraulics Photos
See photos for condition
Beskrivelse Bedømmelse Detaljer  
(12)


Chassis Photos
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Beskrivelse Bedømmelse Detaljer  
(15)
 