Forrige Næste
Slutter
Kan modtage tilbud
 
  
Køb nu pris
CAD 675.000
Du bekræfter denne handling på næste side. Sådan fungerer det. Sådan fungerer Giv bud.
VAREOPLYSNINGER
Måleraflæsning
140 Timer
Serienummer
16 in Intake, 16 in Discharge, Centrifugal Water Pump, 2010 US EPA Label, Cat C27 12 Cylinder 800 hp 27 L Diesel Engine, 8.4 in. particle clearance, 38 in. impeller

Eftersynsrapport



Bemærk venligst, at du som køber er ansvarlig for at gennemse hele eftersynsrapporten, når du evaluerer en vare.


Generelt udseende
Beskrivelse Bedømmelse Detaljer  
CE-mærke No CE mark found
Maling Klik her for at åbne biller og videoer af denne vare.  
Metalplader (fiberglas) tilstand Klik her for at åbne biller og videoer af denne vare.  
(3)


Features
Beskrivelse Bedømmelse Detaljer  
(4)


Control Station - Small
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Beskrivelse Bedømmelse Detaljer  
Måler Operational
Engine Oil Pressure The gauge registers in the operating range.
Fault Indicator Lights Operational
Timetæller (før inspektion) 140.2 hrs Klik her for at åbne biller og videoer af denne vare.  
Timetæller 140 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Klik her for at åbne biller og videoer af denne vare.  
Begrænset funktionstjek The main components are in place and operational as noted.
(4)


Motor
Beskrivelse Bedømmelse Detaljer  
Emission Label Photo Klik her for at åbne biller og videoer af denne vare.  
Blow-by No noticeable vapor or pressure Klik her for at åbne biller og videoer af denne vare.  
Starter Operational
Udstødningssystem Klik her for at åbne biller og videoer af denne vare.  
Køler
Oil Leaks No dripping leaks
Fuel Leaks No dripping leaks
Cooling System Leaks No dripping leaks
Engine - Left Side Klik her for at åbne biller og videoer af denne vare.  
Engine - Right Side Klik her for at åbne biller og videoer af denne vare.  
Limited Function Check The engine started and ran.
(10)


Vandpumpe
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Beskrivelse Bedømmelse Detaljer  
Pumpehus Cast Klik her for at åbne biller og videoer af denne vare.  
Selvspændende system Not functionally checked Klik her for at åbne biller og videoer af denne vare.  
Begrænset funktionstjek (Vandpumpe) Pump appears functional but was not tested with water.
(11)
 
Tvister:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.